• Max Kellermann's avatar
    alsa: better period_time default value for high sample rates · 554a34fb
    Max Kellermann authored
    The default values for buffer_time and period_time were both capped by
    the hardware limits on practically all chips.  The result was a
    period_time which was half as big as the buffer_time.  On some chips,
    this led to lots of underruns when using a high sample rate (192 kHz),
    because MPD had very little time to send new samples to ALSA.
    
    A period time which is one fourth of the buffer time turned out to be
    much better.  If no period_time is configured, see how much
    buffer_time the hardware accepts, and try to configure one fourth of
    it as period_time, instead of hard-coding the default period_time
    value.
    
    This is yet another attempt to provide a solution which is valid for
    all sound chips.  Using the SND_PCM_NONBLOCK flag also seemed to solve
    the underruns, but put a lot more CPU load to MPD.
    554a34fb
To find the state of this project's repository at the time of any of these versions, check out the tags.